What are the common working principles of the liquid level sensor in daily life?

mag 22 2023 2023-05 Sensors Rieker Inc.
Article Cover
You may not know what a level sensor is, but you must know its applications, such as solar power, washing machines, sewage treatment, etc. The measurement principle of the static pressure level sensor is to obtain the pressure value by installing the pressure sensor at the bottom. It is widely used in urban water supply and drainage, sewage treatment, reservoir, river, ocean and other monitoring fields.

You may not know what a level sensor is, but you must know its applications, such as solar power, washing machines, sewage treatment, etc. The measurement principle of the static pressure level sensor is to obtain the pressure value by installing the pressure sensor at the bottom. It is widely used in urban water supply and drainage, sewage treatment, reservoir, river, ocean and other monitoring fields.

You may not know what a level sensor is, but you must know its applications, such as solar power, washing machines, sewage treatment, etc. What are the common liquid level sensors in daily life? How does it work? Today, I'm going to share this process with you.

Common working principle of liquid level sensor:

1. Radar liquid level sensor

The radar level sensor has the same advantages as the laser measurement principle. It is not affected by the measuring medium, is less affected by the external environment, and does not need to be calibrated repeatedly. However, the measuring height is generally less than 6 meters, especially suitable for the measurement of residuum, asphalt and other large containers with heated steam in the tank.

2. Ultrasonic liquid level sensor

The principle of ultrasonic level sensor is to calculate the level height by monitoring the time difference between ultrasonic transmission and reflection. Simple installation, high flexibility, but easily affected by ultrasonic propagation energy loss, not suitable for foam, dust, steam and other absorption environment.

3, static pressure level sensor

The measurement principle of the static pressure level sensor is to obtain the pressure value by installing the pressure sensor at the bottom. The advantage of calculating the liquid level height is that it is not affected by the liquid level height. However, the higher the height, the higher the precision of the liquid level sensor is required. Therefore, it needs to be calibrated when the liquid is used or replaced for a long time. It is widely used in urban water supply and drainage, sewage treatment, reservoir, river, ocean and other monitoring fields.

4. Float type liquid level sensor

Float liquid level sensor is a kind of mechanical detection, through the float up and down to measure the change of liquid level. Repetition accuracy is poor, not suitable for viscous or impurity liquid, easy to cause float jam. Floating ball liquid level sensor is widely used, economical and practical. It is usually used in monitoring fields such as catchment pit, fire pool and sewage treatment. It is not suitable for monitoring fields of food hygiene industry.

5, tuning fork vibration level switch

Tuning fork vibration level switch is widely used in industrial control system, almost applicable to all liquid monitoring fields. For example, plant coolant tanks and lubricant tanks are continuously monitored. The principle is: when liquid or bulk material fills two vibrating forks, by detecting the change of frequency to send a switching signal. The output is a switching quantity and cannot measure continuous height. In addition, the photorefractive measurement emits the light source from inside the sensor through a transparent resin and fully reflects the light source back to the sensor receiver. However, when the liquid level is encountered, some light is only refracted onto the liquid, thus allowing the sensor to detect light volume control of all transparent levels.

I prodotti a cui potresti essere interessato

62054-P2S02 62054-P2S02 XFRMR TOROIDAL 15VA CHAS MOUNT 3526

More on Order

62045-P2S02 62045-P2S02 XFRMR TOROIDAL 10VA CHAS MOUNT 2430

More on Order

62044-P2S02 62044-P2S02 XFRMR TOROIDAL 10VA CHAS MOUNT 6048

More on Order

62043-P2S02 62043-P2S02 XFRMR TOROIDAL 10VA CHAS MOUNT 5472

More on Order

62034-P2S02 62034-P2S02 XFRMR TOROIDAL 7VA CHAS MOUNT 7938

More on Order

62025-P2S02 62025-P2S02 XFRMR TOROIDAL 5VA CHAS MOUNT 3924

More on Order

62021-P2S02 62021-P2S02 XFRMR TOROIDAL 5VA CHAS MOUNT 5058

More on Order

62012-P2S02 62012-P2S02 XFRMR TOROIDAL 3.2VA CHAS MOUNT 3204

More on Order

62005-P2S02 62005-P2S02 XFRMR TOROIDAL 1.6VA CHAS MOUNT 7668

More on Order

62073-P2S02 62073-P2S02 XFRMR TOROIDAL 35VA CHAS MOUNT 5292

More on Order

70074K 70074K XFRMR TOROIDAL 35VA THRU HOLE 6840

More on Order

70072K 70072K XFRMR TOROIDAL 35VA THRU HOLE 5634

More on Order

70031K 70031K XFRMR TOROIDAL 7VA THRU HOLE 8658

More on Order

70024K 70024K XFRMR TOROIDAL 5VA THRU HOLE 8748

More on Order

70013K 70013K XFRMR TOROIDAL 3.2VA THRU HOLE 4392

More on Order

70003K 70003K XFRMR TOROIDAL 1.6VA THRU HOLE 2520

More on Order

62015-P2S02 62015-P2S02 XFRMR TOROIDAL 3.2VA CHAS MOUNT 3780

More on Order

70025K 70025K XFRMR TOROIDAL 5VA THRU HOLE 4068

More on Order

62033-P2S02 62033-P2S02 XFRMR TOROIDAL 7VA CHAS MOUNT 6480

More on Order

62060-P2S02 62060-P2S02 XFRMR TOROIDAL 25VA CHAS MOUNT 23778

More on Order

70005K 70005K XFRMR TOROIDAL 1.6VA THRU HOLE 7218

More on Order

AC1200 AC1200 CURR SENSE XFMR 200A T/H 2142

More on Order

AC1050 AC1050 CURR SENSE XFMR 50A T/H 7362

More on Order

AC1025 AC1025 TRANSFORMER CURRENT 25.0 AMP 4230

More on Order